Features: Large storage, full automatic measurement Automatic qualitative diagnosis of machinery faultsbased on time domain characteristics: Askew index,Kurtosis index Envelope demodulation of acceleration for gears and bearings diagnosis Dual measurement mode:single parameter continuous monitoring All parameters (Acc,Vel, Disp, Envelope) automatic collection Optional: Laser-aimed infrared non-contact Temperature measurement module (integrated). Specifications: Measurement accuracy: + 5%. Frequency span: 100, 200, 500, 1k, 2k, 5k, 10k (Hz). Environmental temperature: 5 - 40 (degrees Celsius) Relative humidity: <85% (non-saturated) The sampling frequency is 2.56 times of the frequency span. Anti-aliasing filter: 8-order ellipse Power supply: Nickel-Hydrogen battery. Work for at least 8 hours continuously after fully charged. Storage capacity for 320 sets of data (including sequential number, Point ID, peak of acceleration, Peak of velocity, peak-peak of displacement, and RMS of envelope) and 48 x 1024-points vibration waveforms. Dimensions: 196 x 101 x 45 (mm) Weight: 1100 grams (including battery) Accessories: 1 accelerometer, 1 magnetic mount, 1 probe, 1 battery charger, 2 cables for sensor and communication, and condition monitoring software MCMe2 |  |  |