I Adept Marketing
I Adept Marketing
I Adept Marketing I Adept Marketing I Adept Marketing I Adept Marketing I Adept Marketing I Adept Marketing I Adept Marketing I Adept Marketing I Adept Marketing I Adept Marketing I Adept Marketing

RH 802


RH802 Spectrum analyzer RH802 Spectrum analyzer is portable but powerful vibration spectrum analyzer developed by very experienced expert and mechanical maintenance expert. Offers some characteristics function, such as long time domain waveform, XPM run-up/down testing characteristics analysis and on site dynamic balance measurement, It is an ideal instruments specialize in doing equipment faults precision diagnosis and single or double plane dynamic balance measurement.
Features The large LCD screen, simple flow chart, compact and light weight, operation more convenient. Very flexible parameters configuration including high and low band pass filter, sampling length and sampling frequency, etc. Meet the requirement of data acquisition. Data acquisition base on scheduled or unscheduled are allowable, unscheduled data acquired can be store by sequence number or by measure point number. Versatile measurement and analysis system Acquiring vibration velocity, acceleration, overall value Measuring time domain waveform, spectrum and long time domain waveform Measuring XPM, cross-power spectrum, phase difference spectrum, and measuring the phase difference between two measure points. Hammering impact response test, measure the natural frequency. Long time domain waveform similar to digital tape recorder, record as long as 2 Mb data, replace tape recorder. Transient data can be recorded, such as rolling mill complete rolling process, and equipment starting state. Run up/down testing analyses, to track the vibration varies in starting and stopping.

RH 802


Single or double plane on site dynamic balance, user can complete dynamic balance test comply with the tips; record all data in the test, or manual input, Continue to do the test, trim balancing until Residual Unbalance is reduced within required balance tolerances, determine that all amplitudes now meet allowable criteria.

Main technical parameters

Items Specification
Analog input -
Channels Channel 1vibrationICP accelerometerVoltage±21V A or DC Channel 2vibrationICP accelerometerVoltage±21V AC or DC tacho
Transducer Accelerometer, Velocity Pickups, Non-contact Eddy Current Displacement Probes, voltage transducer
Signal range ±21V
A/D conversion 16 bit
Analog measurement -
Integration Integrationdouble integration
Maximal analysis frequency 40kHzdouble channel Maximal: 20kHz
Sampling frequency 256Hz - 102.4kHz
Dynamic signal range 96dB
Precision 1% 0.1dB
Signal processing -
Configuration Sampling frequency, High band pass filter, low band pass filter, Sampling lengthuser can set any value
Lines 400, 800, 1600, 3200
Sampling frequency 1024, 2048, 4096, 8192
Window Hanning, Uniform
Averaging Linearity, peak hold
Averages 1,2,4,8,16,32,64,128
Analysis -
Long time domain waveform User input data acquiring time, maximal data size is 2Mb, if use two channels, maximal data size is 1 Mb
XPM view simultaneously cross-power and phase difference spectrum
Dynamic balance On site single or double plane dynamic balance by Influence coefficient method
Run up/down testing with or without order tracking
Basic index -
LCD 320×240pi×les, contrast adjustable
Communication USB 2.0
Battery Rechargeable Li-ion battery, working Time (Continuous) >10 Hours, two channel working time >8 Hours
Temperature (-1050)℃
Humidity 95% RH without condensate
Protection grade IP65
Weight 660g